Volkswagen TSB #TT 87-14-02
2015 Volkswagen e-Golf
TSB Document:
Affected Component: EQUIPMENT:APPLIANCE:AIR CONDITIONER
- Summary
- Tech Tips (e-Golf Evacuating/Filling Refrigerant): When servicing the air conditioning of the e-Golf, The repair manual in Elsa has special instructions and requires additional steps to be performed before evacuating and filling the refrigerant circuit. This document informs Before evacuating the refrigerant the GFF basic setting/ Filling Refrigerant Circuit under C5 Thermal management this software operation must be performed to open all of the system valves.