TSB Document:

Affected Component: ELECTRICAL SYSTEM

Summary
TSB: Some 2019 ? 2020 model year Avalon Hybrid, Camry Hybrid, and RAV4 Hybrid vehicles may exhibit a MIL ON condition with a ?Hybrid System Malfunction? message displayed and one or more of the following DTC(s) that represent an over current between the MG1, MG2, and inverter/PCU: ?P1C5D19 ? Drive Motor "A" Inverter Circuit Current Above Threshold ?P1C5F19 ? Generator Inverter Circuit Current Above Threshold These conditions typically occur on low vehicle mileage (less than 5,000). After an occurrence, the vehicle will be able to run normally with no drivability issues. Follow the Repair Procedure in this bulletin to address these conditions

Click a tab for more information.

Date Published
MAR 10, 2020
NHTSA TSB #
10173802
Find something helpful? Spread the word.

Become a Fan & Spread the Word