Pontiac Engineering Analysis EA07019: POWER SLIDING DOOR
2006 Pontiac Montana
POWER SLIDING DOOR
Latches/Locks/Linkages:Doors:Latch
Structure:Body:Door
Structure:Body:Door:Hinge And Attachments
- Summary
- ODI evaluated General Motors' (GM) data, conducted consumer interviews, inspected and tested MY 2005-2007 GM minivans with regard to the alleged defect of a power sliding door (PSD) opening while the vehicle is out of park.ODI identified a high warranty claim rate.however, these claims are related to various problems associated with doors not properly opening or closing and not specifically to doors opening while driving.the condition of the PSD reversing direction during the closing sequence is consistent with an obstruction of the door, or with improper alignment of the door, and this is addressed in GM technical service bulletin # 07-08-64-007 and bulletins # 07-08-64-007A through D.ODI's evaluation of the PSD system notes numerous safeguards to preclude both unintentional and intentional power opening of the PSD while the vehicle is in motion.a safety-defect trend has not been identified at this time.accordingly, this investigation is closed.[see document file for additional information regarding this resume.]
- Documents (14)
- GM RESPONSE 3/18/2008 DISC ONE Q3,Q5,Q8,Q12,Q15,17 AND DISC TWO HAS Q8,Q8B,Q11 WITH CONFIDENTIAL BUSINESS INFORMATION
- GM RESPONSE 10/24/2008 ORIGINAL IR INFORMATION FROM CD
- GM RESPONSE 10/24/2008 ONE CD TO TIS WITH ATTACHMENTS
- IR TO MFR *10/09/08*P
- CLOSING RESUME APPROVED *02/23/09*P
- TEST/SURVEY REPORT *02/23/09*P
- GM RESPONSE 10/24/2008 LETTER TO ODI
- GM RESPONSE 10/24/2008 BULLENTIN 7-08-64-007D INFORMATION FROM CD
- GM RESPONSE 10/24/2008 BULLENTIN PIC 4845 INFORMATION FROM CD
- GM RESPONSE 10/24/2008 RESPONSE LETTER INFORMATION FROM CD
- GM TSB 07-08-064-007D (JULY, 2008) SUPERCEDES PRIOR EDITIONS
- GM 3/18/2008 LETTER TO ODI
- OPENING RESUME APPROVED *12/11/07*P
- IR TO MFR *01/31/08*
Click a tab for more information.