Mercedes-Benz TSB #LI47.70-P-076030
2023 Mercedes-Benz C300
TSB Document:
Affected Component: EQUIPMENT
- Summary
- Complaint After the charging process is complete, the IC message with charging error appears and the FC P0CFE00 is stored in the "N83 - AC charger for high-voltage battery (SG-LG)" control unit. The fault message and the fault memory entry can also appear during time-delayed charging at the start of the pause in charging. Both only occur in combination with active pre-entry climate control. Cause Software in the "N83 - AC charger for high-voltage battery (SG-LG)" control unit. Remedy Perform SCN coding in control unit "N83 - AC charger for high-voltage battery (SG-LG)".