Mazda TSB #07-003-24
2021 Mazda MAZDA3
TSB Document:
Affected Component: UNKNOWN OR OTHER
- Summary
- Some customers may complain that the ambient temperature on the instrument cluster is displayed more than 50 °F (10 °C) lower than the actual temperature, resulting in insufficient performance of the air conditioning. This is caused by inappropriate soldering in the ambient temperature sensor. To eliminate this concern, the soldering process has been enhanced at the supplier.