Kia TSB #PS393
2016 Kia Soul EV
TSB Document:
Affected Component: EQUIPMENT
- Summary
- PITSTOP: GMI FAULT ON AEROVIRONMENT™ DC FAST CHARGER (LEVEL 3) - WHEN ENCOUNTERING CUSTOMER COMPLAINTS OF A GROUND MONITOR INTERRUPT (GMI) FAULT OCCURRING ONLY WHEN ATTEMPTING TO FAST CHARGE ON AN AEROVIRONMENT (AV) LEVEL 3 CHARGER, FIRST VERIFY THE VEHICLE WILL SUCCESSFULLY CHARGE ON A NON-AEROVIRONMENT LEVEL 3 CHARGER (ABB, SIGNET, ETC.). IF THE GMI FAULT ONLY OCCURS WHEN CHARGING ON THE AEROVIRONMENT LEVEL 3 CHARGER, THE BATTERY MANAGEMENT SYSTEM (BMS) UNIT MAY REQUIRE REPLACEMENT. CONTACT TECHLINE TO RECEIVE ADDITIONAL DIAGNOSTIC GUIDANCE TO RESOLVE THIS CONCERN.