- December 20: No Recall of 50 Million ARC Airbag Inflators, For Now news | 8 days ago
- December 18: Kia Recalls Sorento PHEVs To Prevent Fuel Leaks recalls | 10 days ago
- November 27: Kia EV6 ICCU Recall Issued a Second Time recalls | 31 days ago
- October 26: Kia Carnival Sliding Door Sensor Lawsuit Filed After Recall news | 63 days ago
- October 25: Hyundai and Kia Theft Settlement Final news | 64 days ago
Kia TSB #PS393
2015 Kia Soul EV
TSB Document:
Affected Component: EQUIPMENT
- Summary
- PITSTOP: GMI FAULT ON AEROVIRONMENT™ DC FAST CHARGER (LEVEL 3) - WHEN ENCOUNTERING CUSTOMER COMPLAINTS OF A GROUND MONITOR INTERRUPT (GMI) FAULT OCCURRING ONLY WHEN ATTEMPTING TO FAST CHARGE ON AN AEROVIRONMENT (AV) LEVEL 3 CHARGER, FIRST VERIFY THE VEHICLE WILL SUCCESSFULLY CHARGE ON A NON-AEROVIRONMENT LEVEL 3 CHARGER (ABB, SIGNET, ETC.). IF THE GMI FAULT ONLY OCCURS WHEN CHARGING ON THE AEROVIRONMENT LEVEL 3 CHARGER, THE BATTERY MANAGEMENT SYSTEM (BMS) UNIT MAY REQUIRE REPLACEMENT. CONTACT TECHLINE TO RECEIVE ADDITIONAL DIAGNOSTIC GUIDANCE TO RESOLVE THIS CONCERN.
Click a tab for more information.