Service Bulletin - Water improperly discharged inside the fuel cell stack mixes with hydrogen and oxygen, generating hydrogen peroxide. The hydrogen peroxide/water combination concentrates in one area, accelerating the deterioration of the electrolyte membrane in the fuel cell. This deterioration can reduce fuel cell output.