Honda Engineering Analysis EA21001: Loss of Direction Control
2013 Honda Accord
Loss of Direction Control
Steering
- Summary
- On May 6, 2021, the Office of Defects Investigation (ODI) opened Engineering Analysis (EA21-001) to assess a sudden loss of steering control, in Model Year (MY) 2013-2015 Honda Accord vehicles. Consumers alleged while driving the steering wheel would pull to the left or the right independently. Steering pull may pose a risk of loss of directional control. Honda stated that they believed the inadvertent steering input was caused by a loose magnet located within the electronic power steering (EPS) system. Due to poor formulation of the adhesive, this magnet can become loose and move up to 2 degrees around the steering column. When the magnet moves, the torque sensor generates a signal that results in unwanted steering in either direction. Honda stated the steering force required to maintain directional control with a loose magnet is a maximum of 3-pound feet. The maximum force of the unwanted steering input can be overcome by the driver and is similar to driving on grooved pavement.The Vehicle Research Test Center (VRTC) sent over 4,000 questionnaires to 2013-2015 Honda Accord vehicle owners. Of the 637 responses, 58 consumers experienced unwanted steering. Consumers experiencing unwanted steering did not report difficulties maintaining directional control. There were no crashes or injuries reported to VRTC. Testing done by VRTC was not able to reproduce the allegations. Analysis of all relevant data indicates that the subject condition has a relatively low failure rate. The poor adhesive formulation was addressed by the supplier with three (3) counter measures in the manufacturing process.There has been a declining trend in consumer complaints to NHTSA which indicates possible exhaustion of parts prone to failure. In view of the low rate, declining complaint trend, the nature of failure, and resolution of the adhesive formulation, this Engineering Analysis is closed. The closing of this investigation does not constitute a finding by NHTSA that a safety-related defect does not exist. The agency reserves the right to take additional action if warranted by new circumstances.The ODI complaints cited above can be viewed at www.NHTSA.gov under the following ODI identification numbers: 11538714, 11528538, 11528008, 11522953, 11496557, 11495837, 11494328, 11478680, 11477167, 11476758, 11476263, 11471198, 11470001, 11467026, 11466561, 11466016, 11465626, 11464143, 11463558, 11462759, 11461500, 11460777, 11460191, 11455540, 11454334, 11452198, 11448114, 11447666, 11444888, 11444823, 11444172, 11443324, 11443243, 11443105, 11441374, 11439520, 11438345, 11437261, 11436824, 11436350, 11435994, 11435079, 11434969, 11434545, 11434442, 11434381, 11433824, 11433745, 11433555, 11433368, 11433176, 11431206, 11430465, 11430253, 11430009, 11429253, 11428301, 11427449, 11426841, 11426340, 11425928, 11425261, 11425230, 11423611, 11423245, 11422445, 11422395, 11422351, 11422220, 11422138, 11422069, 11421683, 11421589, 11421540, 11420573, 11419338, 11419270, 11418147, 11418143, 11417768, 11417742, 11417570, 11417437, 11416804, 11416699, 11416401, 11416378, 11416375, 11416155, 11416117, 11416084, 11416051, 11416032, 11416028, 11416024, 11416000, 11415933, 11415915, 11414105, 11406220, 11398736,11387075, 11387049, 11375580, 11364698, 11361125, 11351660, 11349961, 11327909, 11327170, 11301957, 11289067, 11282525, 11277659, 11258017, 11256914, 11218752, 11208077, 11196050, 11194358, 11189901, 11165075, 11163481, 11154891
Click a tab for more information.