Print this page

TSB Document:

Affected Component: EQUIPMENT:ELECTRICAL

Summary
SOME 2015 EDGE,MUSTANG AND F150 VEHICLES WITH A 4" DISPLAY MAY EXHIBIT A 24 HOUR CLOCK DISPLAY THAT RESETS ITSELF TO A 12 HOUR DISPLAY AFTER CYCLING THE IGNITION KEY. TO CORRECT THE CONCERN, REFLASH THE FRONT CONTROL DISPLAY INTERFACE MODULE (FCDIM) TO THE LATEST CALIBRATION USING IDS VERSION 103.05 OR HIGHER. MAKE SURE YOU ARE CONNECTED TO THE INTERNET WHEN ENTERING MODULE PROGRAMMING TO OBTAIN THE LATEST UPDATES. CALIBRATION FILES MAY ALSO BE OBTAINED AT WWW.MOTORCRAFTSERVICE.COM. USE CAUSAL COMPONENT 10D885 AND APPLICABLE 12652A LABOR OPERATIONS FROM SECTION 10 OF THE SLTS MANUAL FOR REFLASH ONLY.

Click a tab for more information.

Date Published
JAN 27, 2017
NHTSA TSB #
10095224
Find something helpful? Spread the word.