Print this page

HVAC Switch Failures

Electrical System:Wiring:Interior/Under Dash

Summary
ODI has received 1 complaint and reports from 4 transportation fleets alleging 182 switch failures.Each fleet operates mini buses built on a Ford E350 or E450 cutaway chassis.The OEM HVAC blower switches have melted, smoked, burned or experienced open flame and become inoperable on vehicles in each fleet.Some drivers have reported a burning smell or smoke coming from the dash.One fleet reported a vehicle fire.No injuries were sustained.However, the bus was carrying special needs children when the driver noticed smoke coming from the dash.The driver was able to evacuate the children prior to the vehicle becoming engulfed in flames.This PE has been upgraded to an Engineering Analysis (EA) to determine if the blower motor switch failures create a situation where a vehicle fire is possible and presents a safety risk to the driver and other passengers.
Documents (7)

Click a tab for more information.

Date Opened
DEC 07, 2009
Date Closed
APR 21, 2010
NHTSA Recall #
No recall issued
  • Status:
    CLOSED
Find something helpful? Spread the word.

Become a Fan & Spread the Word