Ford TSB #SSM 51726
2023 Ford Bronco
TSB Document:
Affected Component: EQUIPMENT
- Summary
- Some 2021-2023 Bronco vehicles may exhibit the HVAC switching out of recirculation without input. This may be due to the air flow mode door inlet strategy while in recirculation mode. This strategy periodically purges the cabin air every 30-60 minutes depending on conditions the vehicle is operated in. If monitoring the Air Inlet Door PID with FDRS, it can go to approximately 50 % movement of the Air Inlet Door while in recirculation mode. During this climate control system strategy operation the recirculation button light should not go off. This is normal operation of the climate control system and no repairs should be attempted. If the recirculation button/light goes off then reference Workshop Manual (WSM), Section 412-00.