Affected Component: EQUIPMENT

Summary
16185-Customer Satisfaction. On certain vehicles, the high voltage interlock connector behind the high voltage battery disconnect relay fuse block cover may be susceptible to becoming recessed back into the high voltage battery disconnect relay assembly. This may cause an electrical disconnect which could result in a loss of vehicle propulsion and/or a no start condition. The malfunction indicator lamp may be illuminated and DTC P0A0C ? ?high voltage system inter-lock circuit low? may be set. A ?Shift To Park? message may also be displayed. Additionally, a subset of these vehicles may have a condition in which the 15A fuse in the high voltage battery disconnect relay may prematurely open. The open fuse may prevent the low voltage battery from being charged by the 14v DC power module. If this were to occur, the vehicle will provide warning to the driver and eventually lose electrical power. Once power is drained from the 12 volt battery, the vehicle may lose propulsion and will not start. Dealers will reprogram the hybrid powertrain control module 2; and if applicable, replace the 15 amp high voltage battery disconnect relay fuse.