Chevrolet TSB #PIC5701B
2015 Chevrolet Volt
TSB Document:
Affected Component: ELECTRICAL SYSTEM:12V/24V/48V BATTERY
- Summary
- This Preliminary Information communication provides information to the technician about the removal of the high voltage battery pack. Technician will need to disable high voltage and fully drain battery coolant before removing the electrical connections. After following the published high voltage disable procedure and properly draining the coolant from the battery cooling system, it may be helpful to use electrical tape to help seal the connections on the battery relay junction block. If coolant does enter these connectors, clean completely with electrical contact cleaner and low pressure compressed air, then apply a light coating of dielectric grease.
Click a tab for more information.