- October 28: Chevrolet Recalls Blazer and Equinox Over Door Strikers recalls | 7 days ago
- October 12: GM Vortec Oil Consumption Lawsuit Dismissed news | 23 days ago
- October 8: Enel X Way Closure and JuiceBox Charger Fires Investigated investigations | 27 days ago
- October 2: Chevrolet Bolt Battery Settlement Preliminarily Approved news | 33 days ago
- September 28: GM Shift to Park Class Action Lawsuit Debated in Ohio news | 37 days ago
Chevrolet TSB #PIT5245D
2015 Chevrolet Tahoe
TSB Document:
Affected Component: ENGINE AND ENGINE COOLING
- Summary
- This Preliminary Information communication provides information to the technician about vehicles that the blower motor may be noisy or vibrate when running. This concern will only occur when the temperatures is below 32 degrees Fahrenheit and if the blower motor is removed while still cold, ice may be found on the blower motor cage. This concern could be caused by water leaking or snow ingestion into the Heater-Vent-Air Conditioning case. Technician is to perform normal water testing diagnostics while the Heater-Vent-Air Conditioning is running, looking for water leaking past the plenum cover. If water is leaking past the cover remove the cover and install a 12x12 snow resistant screen to the fresh air intake. Reseal and install the plenum cover cap using Kent air dry sealer or equivalent. Â
Click a tab for more information.