Chevrolet TSB #PIC6114A
2014 Chevrolet Malibu
TSB Document:
Affected Component: ELECTRICAL SYSTEM:12V/24V/48V BATTERY
- Summary
- This Preliminary Information communication provides information to the technician for a concern with the radio going blank briefly after an auto stop event and the engine is cranking to restart. This concern could be related to an open in circuit 6386 at the x1115 connector. Cavity 34 or 2 of the dual battery control module may be open on these circuits and repair as needed. The negative battery connections at the auxiliary battery should be checked along with using the GR8 battery tester to test the auxiliary battery with the cables disconnected. Check the integrity of the X4 connector at the X50D battery fuse block and make sure the F4UB 175 amp fuse is tight in the X50D battery fuse block.