- December 20: No Recall of 50 Million ARC Airbag Inflators, For Now news | 2 days ago
- December 19: GM Transmission Class Action Lawsuit Update: Appeals Court Ruling news | 3 days ago
- December 18: Chevrolet Equinox EV Recall Issued Over Pedestrian Alert Sounds recalls | 4 days ago
- December 3: GM Truck Tailgate Recall Involves 150,000 HD Trucks recalls | 19 days ago
- November 30: Chevrolet Equinox Caught Fire, Owner Sues Over Fuel Tank news | 22 days ago
Chevrolet TSB #PIC4935D
2011 Chevrolet Colorado
TSB Document:
Affected Component: ELECTRICAL SYSTEM
- Summary
- This Preliminary Information communication provides information to the technician about vehicles that during battery parasitic drain test, there may be some confusion as to what the normal power consumption reading should be from the OnStar system. Technician should understand the power cycles of the various OnStar systems. All Generation 6, 7, 8, and 9 systems are powered up continuously for 48 hours from ignition off. After 120 hours from ignition off, these systems then completely power off. The Onstar modules draw: * IGN ON - 240 to 400 Milliamp. * IGN OFF - 3 to 20 Milliamp for 48 hours or 120 hours on Gen 9 and vehicle communication platforms. * IGN OFF - 0.2 to 0.8 Milliamp after 48 hours or 120 hours on Gen 9 and vehicle communication platforms.
Click a tab for more information.