- November 11: BMW Owner Loses Tip of Thumb in Door, Awarded $1.9 Million news | 9 days ago
- October 27: BMW Diesel Class Action Lawsuit Settlement Approved news | 24 days ago
- October 25: BMW Integrated Brake Recall Issued a Second Time recalls | 26 days ago
- October 11: BMW Water Pump Recall Causes Lawsuit news | 40 days ago
- September 9: BMW X1 Acceleration Lag Lawsuit Filed in Virginia news | 72 days ago
BMW TSB #B120523
2022 BMW i4
TSB Document:
Affected Component: POWER TRAIN
- Summary
- The customer states there is a Drivetrain Malfunction message displayed in the instrument cluster. In addition, the following fault memory entries are saved in the CCU (Combined Charging Unit): 0317F2 - High-voltage system, insulation fault detected: when switch contactors are closed. 0317F1 - High-voltage system, insulation resistance below warning threshold: when switch contactors are closed. The fault memory entries (isolation faults) can occur both individually and in combination, and must be traced back to the eDrive motor based on the ISTA test procedure. If the ISTA test procedure lists the possible cause of fault as âÂÂa metal chip is found behind the brush moduleâ (between the brush module and the end shield of the electrical machine), then a repair is required. Refer to service solution no. 20000794435083 in Aftersales Information Research (AIR). Follow information in the Procedure section below
Click a tab for more information.