- November 11: BMW Owner Loses Tip of Thumb in Door, Awarded $1.9 Million news | 37 days ago
- October 27: BMW Diesel Class Action Lawsuit Settlement Approved news | 52 days ago
- October 25: BMW Integrated Brake Recall Issued a Second Time recalls | 54 days ago
- October 11: BMW Water Pump Recall Causes Lawsuit news | 68 days ago
BMW TSB #B610316
2016 BMW i3
TSB Document:
Affected Component: ELECTRICAL SYSTEM
- Summary
- "SME Fault Code 21F0D2 Causes Erroneous CCM. CCM message ""Drive: Check as soon as possible"" (CCM-ID 49) is displayed during or after charging session with battery heating (preconditioning) active. Fault code ""21F0D2 - High voltage connector: Main switch: stuck negative switch contactor"" stored erroneously due to HV battery heating deactivation too late in the charging process. NOTE: The following consequential faults may be stored as well, but can be ignored until the release of ISTA/P 3.59.0: 21F153 - High voltage connector: safety concept, Level 2: Switch off detected 21F2A9 - SME: Safety Concept, Level 2: Timeout request for protective opening via ACAN SME software"
Click a tab for more information.