TSB Document:

Affected Component: ELECTRICAL SYSTEM

Summary
"SME Fault Code 21F0D2 Causes Erroneous CCM. CCM message ""Drive: Check as soon as possible"" (CCM-ID 49) is displayed during or after charging session with battery heating (preconditioning) active. Fault code ""21F0D2 - High voltage connector: Main switch: stuck negative switch contactor"" stored erroneously due to HV battery heating deactivation too late in the charging process. NOTE: The following consequential faults may be stored as well, but can be ignored until the release of ISTA/P 3.59.0: 21F153 - High voltage connector: safety concept, Level 2: Switch off detected 21F2A9 - SME: Safety Concept, Level 2: Timeout request for protective opening via ACAN SME software"

Click a tab for more information.

Date Published
MAR 01, 2016
NHTSA TSB #
10151182
Find something helpful? Spread the word.

Become a Fan & Spread the Word