BMW TSB #513608
2008 BMW X6
TSB Document:
Affected Component: STRUCTURE
- Summary
- "Outside Door Mirror Moves when Locking or Unlocking the Vehicle. The door mirror tilts immediately after unlocking or locking. The mirror position does not correspond to the memory position preset by the customer. Pressing the seat memory button typically will return the mirror to the stored position. Poor electrical contacts of the mirror drive in the mirror housing INFORMATION The problem has been integrated into ISTA diagnostics. Complete the diagnosis test plan using the latest ISTA version. The test plan can be accessed via the following path: ""Information Search / Function Structure / Body / Mirror / Exterior mirrors / Driver's or passenger side / Exterior Mirror https://www.bmwtis.net/tiscode/cgi-bin/bulletin.aspx?sie_path=/tsb/bulletins/htm_store/15...12/6/2013 Page 2 of 2 Malfunction,"" and then press ""Start Search."" Select the test plan ""AM5102_00010."""