Summary
F48 WITH XDRIVE: FAULT MEMORY ENTRY 440317 IN LMV. The following Check Control Message (CCM) is displayed in the instrument cluster: CCM 350: Driving stabilization. Drive at a moderate speed. The following entry is present in the fault memory of the LMV: 440317 - Pump motor: General multiple fault. Further fault memory entries can occur in combination: DSC: 48068C - Transfer box - clutch closed down temporarily, possible overheating. 48078A - All-wheel drive clutch - clutch position open, only front-wheel drive. LMV: 440304 - Pump motor: Current too low Unfavorable software of the longitudinal torque distribution module (LMV).