Audi TSB #A171558 2038119-
2014 Audi S5
TSB Document:
Affected Component: EQUIPMENT:ELECTRICAL
- Summary
- Supersedes Technical Service Bulletin Group 17 number 14-52 dated September 2, 2014. The message "Oil minimum warning, add one quart of oil" appears in the instrument cluster, but the oil level is above the minimum level (when measured with special tool T40178). There are no DTCs related to oil level stored in the ECM memory. The oil level sensor is defective.