TSB Document:

Affected Component: POWER TRAIN

Summary
The circlip connecting the turbo wastegate actuator rod and the wastegate flap lever can fall of due to low tension of the clip. Consequently, the wastegate linkage becomes disconnected, causing MIL on and DTC P029900.

Click a tab for more information.

Date Published
NOV 17, 2014
NHTSA TSB #
10216705
Find something helpful? Spread the word.

Become a Fan & Spread the Word