- Summary
- Supersedes Technical Service Bulletin Group 97 number 10-15 dated October 20, 2010. Sporadic fault memory entries are stored in various control modules. Contacts may be widened (over 0.63 mm) if incorrect pins or incorrect methods for current flow tests are used. Either action may cause intermittent electrical connections, which can cause sporadic DTCs to be stored in various control modules.